September 13, 2026
Composite Facade Cladding: What It Is and Its Benefits
Composite facade cladding sandwiches a core layer between two thin metal sheets to create a lightweight cladding system. Here is how it works and why it is chosen.

Facade Systems
A facade system in which glass is bonded to the supporting frame with structural silicone, giving an uninterrupted glass appearance.
A structural silicone facade is a curtain wall system in which the glass panels are bonded with structural silicone to an aluminium supporting structure. The supporting structure consists of mullion and transom profiles. No aluminium cap is visible from outside; only the glass surface and the thin joints between the panels can be seen on the facade.
Applications
It is a common choice for business centres, office buildings, hotels, shop and showroom facades, and other buildings that call for a large glass surface.
Advantages
- No cap profile is visible from outside, so the facade looks like one continuous glass surface.
- Large glass surfaces can be created.
- The thermal insulation of the facade can be improved with thermally broken profiles and double glazing.
- Water that enters the facade is drained out through concealed drainage channels inside the profiles.
- Depending on the project, opening sashes with frames hidden from outside, or outward-opening windows, can be added to the facade.
Points to consider
Glass sizes, supporting profile sections and connections must be determined by engineering calculation according to facade height, openings and wind loads. Only structural silicone suitable for structural glazing is used to fix the glass. The compatibility of the glass, the glass coating, the gaskets and the silicone must be checked for every project, and bonding and curing must follow the silicone manufacturer's technical requirements.
On south and west facades, glass is the surface that heats the interior most. Where standard double glazing is not enough, solar control (comfort) glass is used; it cuts solar radiation and UV rays and also keeps the heat inside. Low-E coated glass keeps the heat inside, but it does not cut the sun on its own. The glass type is chosen according to the orientation of the facade and how the interior is used.
When part of a pane is in shade and part in sun, a temperature difference builds up across the glass and causes thermal stress. This risk must be taken into account for large panes and partly shaded facades, and heat-treated glass should be used where necessary.
In a structural silicone facade, the mullions are anchored to the floor slabs. The levelness of the slab edges, projections in the concrete and the plaster allowance are measured at the survey, and the glass sizes are calculated to suit these tolerances. Double glazing units and tempered glass cannot be cut afterwards, so a pane made to the wrong size has to be remanufactured.
Structural silicone must be applied in a clean, dry environment. Bonding is not carried out in rain or very humid weather. The glass is left undisturbed until the silicone has cured.
Glass surfaces are wiped with an ordinary glass cleaner. Sharp scrapers, and products containing acid or solvent, must not be used on the joints, as they damage structural silicone. The joints should be checked by eye at regular intervals, and the installer should be told if the silicone cracks or lifts from the glass.
On tall buildings, cleaning the facade from outside requires a cradle or rope access. If this is not planned at the building design stage, cleaning the facade becomes difficult.
Related guides: Curtain Wall Facade Types: Capped, Semi-Capped, Silicone and Choosing Solar Control Glass for a Hot Climate
Yes. Because each pane is fixed separately, only the broken pane is removed and a new one fitted. However, because the glass is bonded with silicone, replacement needs scaffolding or a platform to be set up and the silicone to be allowed to cure. For this reason, laminated glass is recommended on lower floors where there is a risk of impact.
Yes. A concealed-frame opening sash or an outward-opening window can be added to the facade. The position of the opening sections is planned at the design stage according to the glass division; adding an opening section after the facade is complete is difficult.
The posts and rails are protected against salty air with powder coating or anodising. Because most of the surface visible from outside is glass, maintenance mostly consists of cleaning the glass and joints.
The price is determined by the area and height of the facade, the glass type and thickness, whether the profile has a thermal break, the number of opening sections, the surface colour, and the scaffolding or platform needed for installation. Engineering calculations are made separately for each project.

September 13, 2026
Composite facade cladding sandwiches a core layer between two thin metal sheets to create a lightweight cladding system. Here is how it works and why it is chosen.

September 10, 2026
How wind load affects pergolas, large glass systems and façade cladding, and the profile, glass and installation choices that matter most.

August 2, 2026
Curtain wall facades fall into three main types: capped, semi-capped and structural silicone. Here is how they differ and how to choose between them.