In outdoor structures, wind load is an issue that should be taken into account at the very start of design, yet it is sometimes dealt with only after visual decisions. Pergolas, large-glazed sliding systems and facade cladding form large surfaces that are directly affected by wind. If the profile, glass and installation detail are not chosen according to wind load, problems can appear over time in these structures. This article covers the effect of wind load on pergolas, glass systems and facade cladding, and the points to pay attention to at the design stage.
Why is wind load so important?
The wind load acting on a building element varies with the element's position (height, exposure, surrounding buildings), surface area and orientation. A large glass panel, a closed pergola roof or a large facade panel is a light element that meets the wind with a large surface; for this reason, wind load is a load that must always be considered in the structural calculation for these elements. Strong winds occur from time to time on the Cyprus coastal strip, especially on open terraces and on plots close to the sea, and this should be taken into account in design.
Wind load on pergolas
Wind sensor on motorised (fabric) pergolas
In motorised pergola systems the roof cover is usually a flexible fabric. In strong wind, a cover left open meets the wind with a large surface and can place excessive load on both the cover and the supporting frame. To reduce this risk, a wind sensor is used on motorised pergolas. When the set wind speed is exceeded, the sensor makes the cover retract automatically. Correct adjustment of the sensor and regular testing are important for the system to work as expected in strong wind.
Louvres and drainage on bioclimatic pergolas
Bioclimatic pergola systems have a roof made of aluminium louvres that can rotate about their own axis. In strong wind, when the louvres are brought to a suitable angle, the effect of the wind on the louvre surface and the load on the structure can be reduced. For this reason, in some systems a wind sensor automatically moves the louvres to a safe position. The connection points of the louvres to the supporting frame, the motor power and the profile section should be assessed together at the design stage according to the wind conditions of the area. It is also important that the drainage channels are sized correctly so that rain arriving with strong wind does not collect in the system.

Supporting structure of fixed pergolas
Fixed pergolas have no moving parts, so a wind sensor is not needed. However, the column and beam sections must be chosen with sufficient strength according to the type of roof cover (fabric, timber slats, polycarbonate, etc.) and the wind conditions of the area. Structural calculation is especially important in designs with wide spans and few columns.
Wind load on large glass systems
Deflection control in lift-and-slide and sliding systems
In lift-and-slide and standard sliding doors with large glass, the glass and profile not bending (deflecting) under wind becomes more important as the sash gets wider. Excessive deflection can cause loss of watertightness in the gaskets at the glass edge and, over time, a build-up of stress at the glass edge. That is why in sliding systems with wide openings, the profile wall thickness, reinforcement elements and glass thickness are determined together according to the sash width and wind load. The load-bearing capacity of the tracks and rollers must also be chosen taking into account the sash weight and the additional load the wind can produce; inadequate hardware can cause problems in use over time, even if the glass is sound.
Wind effect on guillotine and fixed glass surfaces
The same principle applies to guillotine glass systems and large fixed glass surfaces: a large glass panel may flex within a certain limit under wind, but there must be no risk of permanent deformation or breakage. The type of glass (tempered, laminated or double glazing) and its thickness should be determined by engineering calculation at the design stage according to the size and position of the panel; the choice should not be based on guesswork. For fixed glass, an adequate bite of the glass in the frame is also important so that the push and suction forces produced by the wind are safely resisted.
Number of locking points on doors and windows
At points with high wind load, the number of locking points on doors and windows is also decisive for strength. Systems that lock at many points fix the sash to the frame at closer intervals, reducing gaps and loss of watertightness that can occur under wind.
Wind load on facade cladding
Composite facade cladding systems have panels fixed to a supporting substructure. The number and spacing of the fixing points and the load-bearing capacity of the fasteners directly determine the facade's resistance to wind load. On high-rise buildings and wind-exposed facades, the suction effect of the wind can be higher at the edges and corners of the facade than in the middle area; for this reason, the fixing points at edges and corners can be placed closer together. Correct design of the air gap behind the panel is also important both for removing moisture and for an even distribution of wind pressure.

How is wind load handled at the design stage?
Wind load is a matter of engineering calculation that varies with the position of the building (open terrace, proximity to the coast, buildings nearby that channel the wind), its height and the surface area of the element. In projects that include a wide-span pergola, a large glass surface or high facade cladding, the profile section, glass and connection detail should be determined at the design stage by assessing site conditions. For exact load values, we recommend examining the local regulations and consulting an authorised engineer.
Common mistakes with wind load
Ignoring wind load on site usually shows up in a few mistakes. The first is enlarging profile and glass sizes on visual preference alone and not taking the wind conditions of the area into account; on open terraces and sea-facing facades, this can cause the elements to tire earlier than expected. The second is not commissioning the wind sensor, or not adjusting it correctly, on motorised pergolas and shutters; an installed sensor may also not give the expected response in strong wind if it is not tested regularly. The third is keeping the fixing frequency at the edge and corner areas of facade cladding the same as in the middle area, although the suction effect of the wind can be more pronounced in these areas. Finally, when choosing hardware such as tracks, rollers and locks for large glass openings, the additional load the wind can produce should be taken into account together with the sash weight.
Frequently asked questions
Is the cover of a motorised pergola damaged in strong wind?
A correctly adjusted wind sensor retracts the cover automatically when the set wind speed is exceeded and reduces the risk of damage to the cover. Checking the sensor regularly is important for the system to work as expected in strong wind.
How do the louvres of a bioclimatic pergola behave in wind?
In some bioclimatic pergola systems, a wind sensor automatically brings the louvres to a safe angle that presents less surface to the wind. The louvre connection points and profile section must be designed according to the wind conditions of the area.
Can wind load break the glass in large glass doors?
When glass of the right thickness and type is determined by project-specific engineering calculation, it stays within safe limits under wind load. The exact glass type and thickness should be determined at the design stage according to the size and position of the panel.
Where does wind affect facade cladding most?
The suction effect produced by wind is generally more pronounced at the edges and corners of the facade than in the middle area. So the strength of the panel can be increased in these areas by increasing the frequency of fixing points.
At what stage should the wind load calculation be made?
The wind load assessment should be made at the design stage, taking into account the position and height of the building and the surface area of the element. For exact load values and regulatory requirements, the local regulations should be examined and an authorised engineer consulted.
To determine the right solution for wind load in your pergola, glass system or facade cladding project, you can contact us and request an assessment specific to your building.